Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
71124 | GENERAL CABLE INDUSTRIES INC. DBA WI |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 580.0 VOLTS PER MIL /0.001 INCH/ |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MOD BY COLOR |
CQBC | MINIMUM TENSILE STRENGTH | 1450 POUNDS PER SQUARE INCH |
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AARX | INSIDE DIAMETER | 0.375 INCHES MINIMUM AND 0.399 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ZZZT | NONDEFINITIVE SPEC/STD DATA | UA SUBFORM AND 3/8 IN. SIZE AND B GRADE AND U FORM AND I CLASS AND 1 CATEGORY AND F TYPE |
ABJH | TEMP RATING | -46.0 DEG CELSIUS AND 70.0 DEG CELSIUS |
AAGT | WALL THICKNESS | 0.022 INCHES MINIMUM AND 0.028 INCHES MAXIMUM |
MATL | MATERIAL | PLASTIC, MIL-I-631, TYPE F, FORM U, SUBFORM UA, GRADE B, CLASS 1, CATEGORY 1 |
HUES | COLOR | CLEAR |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND MILDEW RESISTANT AND OIL RESISTANT |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |